Excellence in high-efficiency gene transfer - optimal for most cell types! |
||||||||||||||||||||||||||||||||||||||||||||||||||||
highlights |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| |
||||||||||||||||||||||||||||||||||||||||||||||||||||
Cell Transfection Reagents |
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® Polyamine Transfection Reagents
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Description
TransIT® -LT (low toxicity) Transfection Reagents offer clear advantages for intracellular delivery of DNA via transfection, including ease of use, transfection reproducibility, and state-of-the-art transfection efficiencies with significantly reduced levels of cell damage. In addition, transfections with TransIT® -LT1 and TransIT® -LT2 do not require media changes and can be carried out in serum-containing media. This unique combination of features makes these transfection reagents ideal for all gene expression studies where the post-transfection state of the cell is important. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cell lines successfully transfected with TransIT® -LT1: |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
| Transfection Efficiency of the TransIT®-LT1 Transfection Reagent on various Cell Lines. | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® -Express Transfection ReagentDeveloped for high-throughput transfections This reagent is gentle enough to place complexes directly on cells at the time of seeding. Transfections can be carried out in serum-containing media and do not require media changes. This results in a time saving of hours to days without sacrificing results. |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® In Vivo Gene Delivery SystemThe first system specifically designed for in vivo applications Features and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionThe TransIT® In Vivo Gene Delivery System is the first product specifically designed to introduce nucleic acids into live mice, allowing for organ-specific genetic studies that were previously impossible to perform on a routine basis. This product contains a unique polymer formulation that facilitates efficient delivery of exogenous DNA complexes into tissues of live mice without the use of potentially harmful viruses. The easy-to-use system consists of two components: a proprietary polymer that forms complexes with the DNA of interest, and a dilution/injection reagent for delivering the DNA into the animal. The DNA is injected into the tail vein of the mouse and target organs are assayed using simple reporter gene assays. The product yields a broad tissue-expression range. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| Mouse liver thin section showing beta -galactosidase reporter gene expression from DNA introduced using the TransIT® In Vivo Gene Delivery System. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® 293 Transfection ReagentFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Description
TransIT®-293 Transfection Reagent was specifically developed to achieve the highest transfection efficiency in HEK 293 cells. This ready-to-use reagent results in 75-85% efficiency using pGFP as the reporter plasmid, with minimal cellular toxicity. Highest transfection efficiencies are achieved when transfections are performed in the presence of serum-containing media, with no media change. MIR 2700 provides sufficient reagent to perform up to 500 transfections in 35 mm dishes. |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
| HEK 293 cells transfected with TransIT®-293 Reagent and pEGFP in complete media for 24 hours. | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® Keratinocyte ReagentFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-Keratinocyte Transfection Reagent was specifically developed to achieve the highest transfection efficiency in keratinocytes. This ready-to-use reagent results in 20-30% efficiency using pGFP as the reporter plasmid, with minimal cellular toxicity. Highest transfection efficiencies are achieved when transfections are performed in the presence of serum-containing media, with no media change. MIR 2800 provides sufficient reagent to perform up to 500 transfections in 35 mm dishes. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| NIKS cells (Stratatech Corporation) transfected with TransIT®-Keratinocyte Reagent and pLacZ for 48 hours. Reporter protein was detected using Mirus' Beta-Galactosidase Staining Kit (MIR 2600). | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT®-HeLaMONSTER™ Transfection ReagentFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-HeLaMONSTER™ Transfection Reagent was specifically developed to achieve the highest transfection efficiency in HeLa cells. This kit, which consists of a TransIT®-HeLa Reagent and a MONSTER Reagent, results in 50-60% efficiency using pGFP as the reporter plasmid, with minimal cellular toxicity. Transfections should be performed in serum-containing media, with no media change. MIR 2900 provides sufficient amounts of both reagents to perform up to 500 transfections in 35 mm dishes. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| HeLa cells transfected with TransIT®-HeLaMONSTER™ Reagent and pEGFP in complete media for 24 hours. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® -TKO: small interfering RNA (siRNA) Transfection ReagentFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Description
The novel TransIT® -TKO reagent enables highly efficient siRNA transfection with significantly reduced levels of cell damage as compared to cationic-liposome based transfection reagents. Transfections are most effective when carried out in complete growth media without a media change or serum addition. When complexed with even low levels of siRNA, TransIT® -TKO reagent successfully knocks out target gene expression in a variety of cell lines. Transgene expression can be silenced either when the siRNA is transfected before, concurrently or after the transfection of the expression vector. These unique features make TransIT® -TKO transfection reagent ideal for all siRNA-mediated gene-silencing studies. It is the only transfection reagent designed to efficiently deliver small interfering RNA to cells in vitro. TransIT® -TKO reagent, combined with the correct siRNA sequence against the target mRNA, can silence endogenous, stable or transient gene expression. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| Knockdown of Luciferase Expression with TransIT-TKO® Reagent in Cos-7 Cells: Reporter plasmids expressing firefly and sea pansy luciferases were transfected into COS-7 cells using TransIT®-LT1 transfection reagent. After four hours various concentrations of anti-firefly luciferase siRNA (0, 0.05, 0.25, 0.75, 1.0, 5.0, 10.0 and 25 nM) were complexed with TransIT-TKO® Transfection Reagent and transfected into the COS-7 cells in their complete media. Twenty-four hours post-transfection, cell lysates were assayed for both firely and sea pansy luciferase expression using Promega's Dual-Luciferase Reporter Assay System. Points indicate percent firefly luciferase expression as compared to the untargeted sea pansy luciferase. |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® 3T3 Transfection KitFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-3T3 Transfection Kit was specifically developed to achieve the highest transfection efficiency in NIH 3T3 cells. This kit, which consists of TransIT®-3T3 Reagent and a 3T3 Authority Reagent, results in 55-65% efficiency using GFP as a reporter, with minimal cellular toxicity. Transfections should be performed in serum-containing media, with no media change. MIR 2180 provides sufficient amounts of both reagents to perform up to 500 transfections in 35 mm dishes. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| NIH 3T3 cells transfected with TransIT®-3T3 Transfection Kit and pGFP (Clontech) in complete media for 24 hours. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
| Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® CHO Transfection KitFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-CHO Transfection Kit was specifically developed to achieve the highest transfection efficiency in CHO-K1 cells. This kit, which consists of TransIT®-CHO Reagent and a CHO Mojo Reagent, results in 50-60% efficiency using GFP as a reporter, with minimal cellular toxicity. Transfections should be performed in serum-containing media, with no media change. MIR 2170 provides sufficient amounts of both reagents to perform up to 500 transfections in 35 mm dishes.. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| CHO-K1 cells transfected with TransIT®-CHO Transfection Kit and pEGFP in complete media for 48 hours. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
| Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® COS Transfection KitFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-COS Transfection Kit was specifically developed to achieve the highest transfection efficiency in COS-7 and COS-1 cells. This kit, which consists of TransIT®-COS Reagent and a COS Boss Reagent, results in 90-95% efficiency using GFP as a reporter, with minimal cellular toxicity. Transfections should be performed in serum-containing media, with no media change. MIR 2190 provides sufficient amounts of both reagents to perform up to 500 transfections in 35 mm dishes. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| COS-1 cells transfected with TransIT®-COS Transfection Kit and pEYFP-Nuc in complete media for 24 hours. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
| Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® Oligo Transfection ReagentFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-Oligo Transfection Reagent was specifically developed for efficiently transfecting a wide range of oligonucleotides and oligoribonucleotides in cells. TransIT®-Oligo provides this high efficiency delivery with the same ease-of-use and high reproducibility found in the rest of the TransIT® line of products. In addition, TransIT®-Oligo reagent transfections do not require media changes and can be carried out in serum-containing media. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| HeLa cells transfected with TransIT®-Oligo Reagent and Cy™3 end labeled phosphothioate DNA oligo in complete media for 24 hours. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® Neural Transfection ReagentFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-Neural™ Transfection Reagent is a novel formulation specifically developed to achieve superior transfection efficiency in a wide range of neural cell types without sacrificing cell viability. This ready-to-use reagent results in up to 85% efficiency using pGFP as the reporter plasmid. Highest efficiencies are achieved when transfections are performed in the presence of serum-containing media, with no media change. MIR 2140 provides sufficient reagent to perform up to 500 transfections in 12-well plates.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
| C6 cells transfected with TransIT®-Neural™ Transfection Reagent and pEGFP in complete media for 48 hours.. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT® Insecta Transfection ReagentFeatures and Advantages
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product DescriptionTransIT®-Insecta™ Transfection Reagent was specifically developed to achieve the highest transfection efficiency in insect cell lines. This ready-to-use reagent results in 20-30% efficiency using B-galactosidase reporter vector, with minimal cellular toxicity. This unique formulation of lipids makes TransIT®-Insecta™ Transfection Reagent ideal for expressing genes and transfecting with recombinant baculovirus expression systems. MIR 2200 provides sufficient reagent to perform up to 250 transfections in 35 mm dishes. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| Sf9 cells transfected with a Beta-galactosidase reporter vector using TransIT®-Insecta™ Reagent. Reporter protein was detected using Mirus' Beta-Galactosidase Staining Kit (MIR 2600).. | ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
| Download: product information
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
TransIT®-Prostate Transfection Kit
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
| ORDER INFORMATION, SHIPPING & STORAGE: | ||
| order# | description | amount |
| MIR 2134 | TransIT® Prostate Transfection Reagent | 0.4 ml |
| MIR 2130 | TransIT® Prostate Transfection Reagent | 1 ml |
| Shipped on blue ice; store at 4°C. Do not freeze. | ||
The TransIT-TKO® Reagent is supplied as a dry film on clear plastic, sterile, 96-well plates which have flat-bottom wells suitable for cell culture. Each plate is supplied individually vacuum sealed in a foil pouch to maintain sterility and ensure effectiveness. Researchers can test up to eight different siRNA sequences in triplicate format, at four different levels of reagent, from L1 (lowest) to L4 (highest), using the TransIT-TKO® HTS-96 Titration Plate (MIR 2530), on their particular cell type. Once the optimal level has been determined based on the highest efficiency of transfection with the lowest cellular toxicity, additional plates can be purchased at the desired level. Transfections can be performed using a single TransIT-TKO® HTS-96 Plate or using a two step transfer method, where the TransIT-TKO® HTS-96 Plate is used as a reagent plate to form complexes and transfer to the plate of choice.
Download: product information
| ORDER INFORMATION, SHIPPING & STORAGE: | ||
| order# | description | amount |
| MIR 2530 | TransIT® HTS-96 Titration Plate | 1 plate |
| MIR 2540 | TransIT® HTS-96 Level 1 Plate | 1 plate |
| MIR 2545 | TransIT® HTS-96 Level 1 Plate | 5 plates |
| MIR 2550 | TransIT® HTS-96 Level 2 Plate | 1 plate |
| MIR 2555 | TransIT® HTS-96 Level 2 Plate | 5 plates |
| MIR 2560 | TransIT® HTS-96 Level 3 Plate | 1 plate |
| MIR 2565 | TransIT® HTS-96 Level 3 Plate | 5 plates |
| MIR 2570 | TransIT® HTS-96 Level 4 Plate | 1 plate |
| MIR 2575 | TransIT® HTS-96 Level 4 Plate | 5 plates |
| Shipped on blue ice; store at 4°C. Do not freeze. | ||
The TransIT®-Jurkat Transfection Reagent is specifically optimized to provide superior transfection efficiency in Jurkat cells. Jurkat cells (human T-lymphocyte; acute T-cell leukemia) have been inherently difficult to transfect, yet have remained a prevalent cell line in the immunological research field. The specificity of the TransIT®-Jurkat Transfection Reagent makes this product a desirable alternative to broad spectrum transfection reagents. The reagent provides many attributes of the trusted TransIT® Reagent line: high efficiency, simplicity of use, and reproducibility. Transfections with the TransIT® Reagents do not require media changes and can be carried out in serum-containing media. These significant features establish the TransIT®-Jurkat Transfection Reagent as the product of choice for transfecting Jurkat cells.
![]() |
![]() |
| Jurkat, Clone E6-1 cells transfected with TransIT®-Jurkat Transfection Kit and pEGFP (Clontech) in complete media for 48 hours (green). Cells were fixed and then counter-stained with To-Pro-3 (Molecular Probes) to show cell nuclei (blue). | |
Download: product information
| ORDER INFORMATION, SHIPPING & STORAGE: | ||
| order# | description | amount |
| MIR 2124 | TransIT®-Jurkat Transfection Reagent | 0.4 ml |
| MIR 2120 | TransIT®-Jurkat Transfection Reagent | 1 ml |
| MIR 2125 | TransIT®-Jurkat Transfection Reagent | 5 x 1 ml |
| MIR 2126 | TransIT®-Jurkat Transfection Reagent | 10 x 1 ml |
| Shipped on blue ice; store at 4°C. Do not freeze. | ||
The TransIT®-mRNA Transfection Kit is optimized for efficient delivery of various types of RNA to mammalian cells. Both mRNA and viral RNA of various lengths can be delivered effectively to a wide range of cell types. In addition, transfection of mRNA leads to high level protein expression with minimal cytotoxicity. As an added benefit, this kit has been optimized for use in the presence of serum containing media thus eliminating media changes or serum addition. MIR 2250 provides sufficient reagents to perform up to 500 transfections per well of a 12-well plate.
Cell lines successfully transfected: A549, CHO-K1, COS-7, HEK 293, HeLa, HepG2, NIH 3T3, and Vero cell lines.
Download: product infomation and FAQ's
| ORDER INFORMATION, SHIPPING & STORAGE: | ||
| order# | description | amount |
| MIR 2225 | TransIT®-mRNA Transfection Kit | 0.25 ml |
| MIR 2250 | TransIT®-mRNA Transfection Kit | 0.5 ml |
| MIR 2255 | TransIT®-mRNA Transfection Kit | 5 x 0.5 ml |
| MIR 2256 | TransIT®-mRNA Transfection Kit | 10 x 0.5 ml |
| Shipped on blue ice; store at 4°C. Do not freeze. | ||
TransIT®-siQUEST™ Transfection Reagent enables highly efficient siRNA transfection with significantly reduced levels of cell damage as compared to cationic-liposome based transfection reagents. Transfections are most effective when carried out in complete growth media, with no media change or serum addition required. TransIT®-siQUEST™ Reagent efficiently delivers siRNA to a wide range of cell lines, promoting high levels of target gene expression knockdown. These unique features make the TransIT®-siQUEST™ Transfection Reagent ideal for siRNA-mediated gene silencing studies. The TransIT®-siQUEST™ Reagent is a complement to Mirus' popular TransIT-TKO® siRNA Transfection Reagent. Each unique formulation provides a distinct transfection profile for high efficiency, broad-spectrum siRNA delivery.
Cell Lines Successfully Transfected: A549, CHO-K1, COS-7, HEK 293, HeLa, Hepa1c1c7, HepG2, MCF-7, NIH 3T3, RAW 264.7, and Vero cells.
Download: product information and FAQ's
| ORDER INFORMATION, SHIPPING & STORAGE: | ||
| order# | description | amount |
| MIR 2114 | TransIT®-siQUEST™ Transfection Reagent | 0.4 ml |
| MIR 2110 | TransIT®-siQUEST™ Transfection Reagent | 1 ml |
| MIR 2115 | TransIT®-siQUEST™ Transfection Reagent | 5 x 1 ml |
| MIR 2116 | TransIT®-siQUEST™ Transfection Reagent | 10 x 1 ml |
| Shipped on blue ice; store at 4°C. Do not freeze. | ||
For more Mirus products, please download the Mirus catalog (1.8 MB).


home | search | site map | order | Impressum |