Products | Lab Supplies

 

Mobicol "F"

 
     
 

The versatile small column with inserted filter for affinity chromatography!

Content
button Mobicol "F"
  button Order Information
button MobiSpin Column "F"
  button Order Information
button Mobicol "classic"
  button Order Information
button Accessories
  button Order Information
button Related Products: Matrices

 
  Mobicol

 

Features

  • Convenient snap off plug
  • From a very few to up to 700 µl
  • Autoclavable at 110 °C for 10 min
  • Let it drain by gravity flow or spin it
  • Compatible with minifuges and 1.5 – 2 ml cups
  • Additional cap with Luer-lock connection
 
  Free Mobicol “F” sample on request   Mobicol  
 
Mobicol
 
     
 

The Mobicol “F” columns for affinity chromatography are compatible to the laboratory standard. With affinity matrix they are convenient for:

 
  Mobicol  
  • Purification of peptides
  • Purification of tagged proteins
  • Purification of native proteins (using immobilized IgG, NTP-binding proteins, β-lactamase, Igase, peroxidase, erythropoietin, β-galactosidase)
  • Fractionation and purification of antibodies (using protein A/G, immobilized epitopes, peptide matrix)
  • Purification of glycoproteins, and carbohydrates
  • Purification of fatty acids and fatty acid binding proteins
  • Whole mount embryo in situ hybridization

A filter of 35 µm pore size is inserted and a separately available upper filter conveniently caps the resin bed. The columns can be closed tightly with a screw-on cap and a snap-off plug at the outlet.
 
     
     
 

Order Information


order # description
amount
M105035F Mobicol "F" with fixed outlet plug, inserted 35 µm filter and 2 different screw caps 50
M1050 Mobicol "F" with fixed outlet plug and 2 different screw caps, without filters 50
M1053 Mobicol "F" with fixed outlet plug and 1 closed screw cap, without filters 50
M2210 Filter (large) 10 µm pore size, for Mobicol M1002, M1003, M1050 & M1053 50
M523515 Filter (large) 35 µm pore size, for Mobicol M 1002, M1003, M1050 & M1053 50
M2290 Filter (large) 90 µm pore size, for Mobicol M1002, M1003, M1050 & M1053 50
 

 

Related Products

The Mobicol "F" columns are available prefilled with immobilized proteases, nucleases, alk. phosphatase, ß-galactosidase or a compound of your choice on request.


Back to top


 
 

MobiSpin Column "F"

 
 

The universal spin column for centrifugation!

Content
button Mobicol "F"
  button Order Information
button MobiSpin Column "F"
  button Order Information
button Mobicol "classic"
  button Order Information
button Accessories
  button Order Information
button Related Products: Matrices

 
 

Features

  • Column with filters of 10 µm pore size
  • Column volume is 700 µl
  • Fill in the matrix of your choice
  • Can be centrifuged in 1.5 ml or 2 ml tubes and fits all common centrifuges
  • Autoclavable at 110 °C for 10 min


  Mobicol  
 


The MobiSpin Column "F" is convenient for diverse applications. You can fill in your matrix of your choice and spin the column in every common centrifuge in 1.5 ml oder 2 ml cups. For prefilled MobiSpin Columns "F" please see the related products.
For example you can use MobiSpin Columns "F" with gel filtration matrix for:

  • Removal of unicorporated dyes or dye terminators for purification of DNA after labeling reactions
  • DNA purification prior to sequencing
  • Removal of free nucleotides
  • Oligonucleotide purification after synthesis


 
  Mobicol   The column can be tightly closed with the screw cap. Snap off the outlet plug for emptying the column and use the reverse side of the plug for closing.  
 


Order Information


order # description
amount
M105010S MobiSpinColumn "F" with fixed outlet plug, inserted small 10 um filter and screw cap 50
M105210S MobiSpinColumn "F" with fixed outlet plug, inserted large 10 um filter and screw cap 50


For further information please download our Mobicol-Brochure.


Related Products

The MobiSpin Columns "F" are available prefilled with: Sephadex® G50, Sephacryl® S-200, S-300 and S-400, or a compound of your choice on request.

order # description
amount
SCO500 MobiSpin Column "F" prefilled with Sephadex® G50 20
SCO200 MobiSpin Column "F" prefilled with Sephacryl® S-200 20
SCO300 MobiSpin Column "F" prefilled with Sephacryl® S-300 20
SCO300 MobiSpin Column "F" prefilled with Sephacryl® S-400 20
(Sephadex® and Sephacryl® are registered trademarks of Amersham Biosciences, Inc.)

Back to top
 
 

Mobicol "classic": Centrifugable and Autoclavable 1 ml Columns

 
 

The Mobicol "classic" for affinity chromatography and centrifugation!

Content
button Mobicol "F"
  button Order Information
button MobiSpin Column "F"
  button Order Information
button Mobicol "classic"
  button Order Information
button Accessories
  button Order Information
button Related Products: Matrices


 
 

Features

  • Can be centrifuged in minifuges
  • Autoclavable at 120°C (with filters at 110°C)
  • Have Luer-lock connectors
  • Are compatible with laboratory standard
  • Smallest and largest volumes can be treated easily
  • Luer adapters available for tubing
  • Can be closed tightly with a screw cap and a plug at the outlet
  • Actual volume is 800 µl

 
Mobicol with two different lids (Luer-lock and screw cap), two filters and outlet plug. Actual volume: 800 µl. Scale: enlarged. Mobicol "classic" with two different lids (Luer-lock and screw cap), two filters and outlet plug. Actual volume: 800 µl. Scale: enlarged .
 
 
Mobicol
Mobicol "classic": centrifugable 1 ml column (actual volume with small lower filter 800 µl);
 


Filters:

Filter of the pore sizes 10 µm, 35 µm or 90 µm are available separately for Mobicol "classic". The filters can be inserted easily with the help of a plastic tool, which is delivered with the columns. The upper large filter fits tightly over the whole length of the column body.

Empty spin columns:
Since Mobicol "classic" can be centrifuged in minifuges, they are also excellent as spin columns. Our empty spin columns come with screw-cap, inserted filter (10 µm) and bottom plug.

 
 

Order Information

For a detailed data sheet as a pdf-file, please click on the order#.
Free Mobicol "classic" samples on request.
order # description amount
M1002 Mobicol "Classic" with 2 different screw caps without filters 50
M1003 Mobicol "Classic" with 1 closed screw cap, without filters 50
M1002S Empty Spin Column with closed screw cap, inserted plug and large 10 µm filter 100
M2110 Filter (small) 10 µm pore size, for Mobicol M1002, M1003, M1050 & M1053 50
M513515 Filter (small) 35 µm pore size, for Mobicol M 1002, M1003, M1050 & M1053 50
M2190 Filter (small) 90 µm pore size, for Mobicol M1002, M1003, M1050 & M1053 50
M2210 Filter (large) 10 µm pore size, for Mobicol M1002, M1003, M1050 & M1053 50
M523515 Filter (large) 35 µm pore size, for Mobicol M 1002, M1003, M1050 & M1053 50
M2290 Filter (large) 90 µm pore size, for Mobicol M1002, M1003, M1050 & M1053 50
Filters have to be ordered separately. Two filter insertion tools (for small and large filters) are provided with each pack of columns. Lab column set and accessories.


For further information please download our Mobicol-Brochure.

Back to top

 
 

Accessories

 
 

Variable Accessories are available for the Mobicols and Lab Columns:

 
 
Content
button Mobicol "F"
  button Order Information
button MobiSpin Column "F"
  button Order Information
button Mobicol "classic"
  button Order Information
button Accessories
  button Order Information
button Related Products: Matrices
 
Fig. A Tubing-to-Luer-lock adapter. Scale: reduced
 
 
    • Tubing-to-Luer-lock adapter for Mobicols or laboratory columns (Fig. A)
    • Luer-adapter for the top-cap (M), Luer-adapter for outlet (F) and Luer-lock adapter (M)/(M) (Fig. B)
    • One-way stopcocks, Luer-lock (Fig. C)
    • Different small and large filters

 
 
Fig. B Adapters for connecting tubing to
the columns. Luer-adapter for the top-cap
(M); Luer-adapter for outlet (F), Luer-lock-
adapter (M/M)
Fig. C One-way stopcock
 
 

Order Information

order # description amount
M3001 Tubing-to-Luer-lock adapter (material outside: metal; inside: glass and PTFE; with 1 m PTFE tubing) for Mobicols or laboratory columns 1
M3002 Luer-adapter, (M) and (F) 10 each 20
M3003 Luer-adapter for the top-cap (M) 20
M3004 Luer-adapter for outlet (F) 20
M3007 Luer-lock adapter (M)/(M) 1
M3005 Bottom plugs for M 1002 50
M3006 Stopcocks, one-way, Luer-lock 4
M3009 Luer-lock caps 50



For further information please download our Mobicol-Brochure.

Back to top



 
 

Related Products: Matrices

order # description amount
AC-201-10-JB 6% CL-Glutathione ChroMatrix(TM), Bulk material - 10 ml 10 ml
AC-303-25-JB High Density Nickel Agarose, Bulk material - 25 ml 25 ml
AC-304-25-JB Low Density Nickel Agarose, Bulk material - 25 ml 25 ml
AC-305-25-JB High Density Zinc Agarose, Bulk material - 25 ml 25 ml
AC-202-10-JB 6% CL-Nickel ChroMatrix(TM), Bulk material - 10 ml 10 ml
AC-309-5-JB Protein A Agarose, Bulk material - 5 ml 5 ml
AC-101S-JB Immobilized gamma-Aminophenyl-ATP (C10-spacer), Bulk material - Agarose 1 ml
AC-102S-JB Immobilized gamma-Aminophenyl-ATP (no spacer), Bulk material - Agarose 1 ml
AC-106S-JB Immobilized gamma-Amino-octyl-GTP, Bulk material - Agarose 1 ml
AC-107S-JB Immobilized gamma-Amino-octyl-UTP, Bulk material - Agarose 1 ml
AC-108S-JB Immobilized gamma-Amino-octyl-CTP, Bulk material - Agarose 1 ml
AC-109S-JB Immobilized gamma-Amino-octyl-ITP, Bulk material - Agarose 1 ml
AC-110S-JB Immobilized gamma-Amino-octyl-XTP, Bulk material - Agarose 1 ml
AC-111S-JB Immobilized gamma-Amino-octyl-dATP, Bulk material - Agarose 1 ml
AC-115S-JB Immobilized gamma-Amino-octyl-dTTP, Bulk material - Agarose 1 ml
AC-119S-JB Immobilized gamma-Amino-hexyl-CTP, Bulk material - Agarose 1 ml
AC-120S-JB Immobilized gamma-Amino-hexyl-ITP, Bulk material - Agarose 1 ml
AC-121S-JB Immobilized gamma-Amino-hexyl-XTP, Bulk material - Agarose 1 ml
AC-122S-JB Immobilized gamma-Amino-hexyl-dATP, Bulk material - Agarose 1 ml
AC-124S-JB Immobilized gamma-Amino-hexyl-dUTP, Bulk material - Agarose 1 ml
AC-137S-JB Immobilized O-Phospho-L-Serine (C10-spacer), Bulk material - Agarose 1 ml
AC-139S-JB Immobilized O-Phospho-L-Threonine (C10-spacer), Bulk material - Agarose 1 ml
AC-103S-JB Immobilized O-Phospho-L-Tyrosine (C10-spacer), Bulk material - Agarose 1 ml
AC-104S-JB Immobilized O-Phospho-L-Tyrosine (no spacer), Bulk material - Agarose 1 ml
AC-142S-JB Immobilized 2'/3'-EDA-m7GTP, Bulk material - Agarose 1 ml
AC-144S-JB Immobilized 2'/3'-EDA-ADP, Bulk material - Agarose 1 ml
AC-145S-JB Immobilized N6-(6-Amino)hexyl-AMP, Bulk material - Agarose 1 ml
AC-146S-JB Immobilized 8-Amino-hexyl-cAMP, Bulk material - Agarose 1 ml
AC-147S-JB Immobilized 2'-EDA-cAMP, Bulk material - Agarose 1 ml
AC-148S-JB Immobilized 2'-EDA-cGMP, Bulk material - Agarose 1 ml


For further information please download our Mobicol-Brochure.

 
     
  Go Order   Back to top